Calculating the real and reactive power of a transmission line. Facts devices provide an opportunity to resolve congestions by controlling active and reactive power flows as well as voltages. Since it is referred to the generator delivered power if it is negative that means the generator is underexcitated and gets reactive power from the gridinfinite. Shunt compensation of reactive power can be employed either at load level, substation level, or at transmission level. Reactivepower control in electrical power transmission. Power factor is a measure of the relation between real and reactive power. All nodes, connation points of other transmission lines, distribution station and other equipment contribute to reactive power flow a transmission line itself is also a source of reactive power. Proactive and reactive transmission power control for.
Reactive power support of distribution and transmission. The circulation of active power over time results in active energy in kwh. A simplified model of a transmission system with shunt compensation is shown in figure 1. If is23 a then line reactive power it is xis223268. Under light load, the line generates more reactive power than it consumes. Real and reactive power flow control using flexible ac. Voltage levels and reactive power flow must be carefully controlled to allow a power system to be operated within acceptable limits. In addition, other fixed and variable expenses are. Reactive power generation consumption note that a transmission line both absorbs and generates reactive power. In a power system, the goal is to maximize the utilization of the transmission. Under surge impedance loading, the line generates and consumes the same amount of reactive power. Reactive power q it is a consequence of an ac system. The optimization can be done by adjusting reactive power in the transmission line.
L c x v q 17 from the power angle curve shown in figure 1. The voltage magnitudes of the two buses are assumed equal as v, and the phase. Enhancement of power quality in transmission line using. In many cases the cheapest sources of real power are located remotely from load centers, and system operators have to monitor voltage levels within the load centers to ensure a constant voltage. Proactive and reactive transmission power control for energy. Steel plant performance, power supply system design and power quality aspects power quality leads to improved production and. This fact suggests that the transmission power must adapt to the current state of the link in a way that it ensures a balance between energy consumption and packet loss. Transformer reactive power requirement electric power. Increased reactive and apparent power will devrease the power factor pf. Aug 30, 2017 reactive power and voltage relationship in power transmission line. This value differs from the available reactive power support by the ders and other sources of reactive power.
Why is it desirable to inject reactive power into a. Reactive power compensation rpc offers the most economic mean s to do so. No dc power in the field circuit will be converted into reactive power. Reduce losses in the transmission and distribution system. Active power relates to the resistive loads like electric heaters, lamps, and etc. Motor loads and other loads require reactive power to. Importance of reactive power in power generation and transmission. Determine consumed power from activereactive components. Reactive power vars is required to maintain the voltage to deliver active power watts through transmission lines indexing of active power consumption is called reactive power electromechanical devices and other loads require reactive power reactive power deficiency causes the voltage to sag down.
Importance of reactive power in power generation and. You can avoid this additional fee by increasing your power. Compensation should be provided as close as possible to the consumption point to avoid having to distribute this power in the other part of network. Accordingly, utility charges for maximum demand, active energy and reactive power drawn as reflected by the power factor in its billing structure. It can be capacitive leading or inductive lagging reactive power, although in most. Note that the compensation might be both positive and negative reactive power in, or reactive power out. It constitutes voltage and current loading of circuits but does not result in an average active power consumption and is, in fact, an important component in all ac power networks. In a transmission system, there is a strong correlation between reactive power and voltage magnitude, whereas the active power is mainly dependent on the voltage angle. A quote from the roger c dugan, the author of this textbook on electrical power systems. When the loading of a transmission line is heavier than its sil, the voltage will be decreasing along the line. Next i calculated it with the line resistance factored in then got the result for q as. Using these i want to calculate the amount of reactive power sent by the sending end as well. How reactive power is helpful to maintain a system healthy. In effect, the transmission line is a series reactance.
Sep 10, 2018 over a long distance power transmission, additional reactive power losses occur due to the large reactive impedance of high voltage transmission system. This reactive power is expressed in kilo var or mega var. Reduce losses in the transmission and distribution system 1. Apr 01, 2014 conclusion from all the previous discussion we can conclude reactive power compensation is a must for improving the performance of the ac system. To avoid excessive reactive power transmission, generation and consumption of reactive power should be as close as possible to each other. This loss applies whenever an imaginary component is present not just for motors. Transmission and distribution reactive power compensation for. A short transmission line is one whose length is less than 80 km. On the other hand a series compensator interposed in the transmission line as shown in fig. On a long transmission line, a large part of the voltage drop may be reactive, caused by the inductive reactance of the line itself.
Traditionally, facts devices can only regulate either the active power flow or reactive power flow of a single transmission line. Active and reactive power flow control using facts devices. Until a few years ago, the ability to generate reactive power. These three types of powertrue, reactive, and apparentrelate to one another in trigonometric form. Reactive power can be stated as the amount of unused power that is developed by reactive components, such as inductors or capacitors in an ac circuits.
Reactive power compensation of transmission lines by. The maximum shortcircuit reactance tolerance is used when calculating the maximum reactive power consumption, and the minimum shortcircuit reactance tolerance is used when calculating the minimum reactive power consumption. Reactive power must be supplied to most types of magnetic equipment, such as motors and transformers. Reactive power vars is required to maintain the voltage to deliver active power watts through transmission lines. It can be visualised as the sea on which the boat of active power sails. In recent years, the reactive power control has been the subject of a systematic study as it plays an important role in maintaining a secure voltage profile in a large scale transmission system. Economic load dispatch and optimal power flow in power. Transmission line parameters include resistance and inductance. Another technique by the muhammad jafar, marta molinas improvement in reactive power consumption of line commutated hvdc converters for integration of offshore wind power l. Reactive power compensation technologies accessscience from.
The voltage on customer side will decrease further. A heavily loaded transmission line consumes reactive power, decreasing the voltage of the line whilst a lightly loaded transmission line generates reactive power, increasing the voltage of the line. It creates an extra load on the installation, equipment and transport infrastructure such as cables and pipes. Reactive power uncompensated transmission lines passive compensa reactivepower control in electrical power transmission systems wileyieee press books ieee websites place cookies on your device to give you the best user experience. Dec 09, 2019 the demand for active power is expressed in kilowatts kw or mega watts mw. Importance of reactive power for system electrical notes. Such interfaces measure power flows across select high voltage transmission lines into remote load centers to indicate when additional local generation within the load center is necessary to maintain voltage levels. The primary challenge of utilizing reactive power to manage voltage is that reactive power does not travel as far as real power in an electric system. When the system is without any facts device, the power angle oscillations can not be controlled as shown in fig. Any of these limits can be more or less important in different circumstances. Under heavy load, the line absorbs more reactive power than it generates. For understanding the relationship between the reactive power flow in a transmission line and voltage drop, we will consider short transmission line for simplicity.
Apparent power s or total power s is the combination of active and reactive power. Reactive power is something we can describe as a necessary evil. Power factor correction electrical loss 2 between power plant and useful work output of motor was the transmission and transformer i2r and hysteresis losses resulting from the imaginary component of the power. A technique is known as reactive compensation is used to reduce apparent power flow to a load by reducing reactive power supplied from transmission lines and providing it locally. Transmission line resistance results in active power loss and inductance. Another parameter affecting reactive power consumption of converters on the inverter side is dc line resistance. Voltage support is generally required to reduce voltage fluctuation at a given terminal of a transmission line. Power triangle relating apparent power to true power and reactive power. Today, reactive power is present in many installations. Sssc location will be taken on the basis of reactive power flow through the.
The capacity of a transmission line is often limited by the amount of voltage drop that the online tap changers can correct. Importance of reactive power voltage control in an electrical power system is important for proper operation for electrical power equipment to prevent damage such as overheating of generators and motors, to reduce transmission losses and to maintain the ability of the system to withstand and prevent voltage collapse. Though it is a byproduct of alternating current systems, it is needed for the acceptable functioning of vari. How is reactive power generated in transmission lines. Transmission lines dissipate reactive power more quickly than real power, meaning that reactive power cannot be efficiently transferred long distances on transmission lines. Voltage control in an electrical power system is important for proper operation for electrical power equipment to prevent damage such as overheating of generators and motors, to reduce transmission losses and to maintain the ability of the system to withstand and prevent voltage collapse. Static compensator statcom can be used to adjust the reactive.
This power should be supplied from electrical generating station. Reactive power compensation in transmission systems also improves the stability of the ac system by increasing the maximum active power that can be transmitted. Nov 21, 2012 conclusion voltage control is essential to reduce transmission losses and to maintain the ability of the system to withstand and prevent voltage collapse decreasing reactive power causing voltage to fall while increasing it causing voltage to rise raising power factor is a proven way of increasing the efficient use of electricity by utilities. A lightly loaded line acts as reactive power generator while heavily loaded line acts as absorber of reactive power. Profilee lectricity losses occur at each stage of the power distribution process,1 beginning with the stepup transformers2 that connect power plants to the transmission system, and ending with the customer wiring beyond the. Calculating the reactive power of a transmission line. And when the resistance is factored in, the sign of q is negative indicating the generator bus is absorbing vars which doesnt seem to make sense. These inductive loads are generally electromagnetic circuits of electric motors, electrical transformers, the inductance of transmission and distribution networks, induction furnaces, fluorescent lightings, etc. Chapter 3 reactive power role and its controllability in. Reduce your reactive power improves efficiency and saves costs.
Capacitor bank reactive power compensation electrical4u. All the arrangements in electrical pomes system are done to meet up this basic requirement. In this paper, we validate our two transmission power level policies reactive and predictive approaches using the castalia simulator. The reactive power is essential for creating the needed coupling fields for energy devices. Reactive power and voltage control of a transmission line. Low power factor requires an increase in the electric utilitys generation and transmission capacity to handle the reactive power component caused by inductive loads. I am utilizing one of schneider electrics energy meters for measuring energy consumption. In short lines, where series reactance x is relatively small, the. Local control of voltage by means of autotransformers will lead to increase of current to get the same power and this in turn will increase voltage drops in lines. These are used for active power injection as well as harmonic and reactive power compensation in the grid systems by photo voltaic power. Reactive power can arise in the external network and in the local network, and may be caused by the energy supplier as well as the end user.
Reactive power should be minimized because it increases the overall current flowing in an electric circuit without providing any work to the load. Increased reactive currents only provides unrecoverable power loss due to power line resistance. True power, reactive power, and apparent power for a resistivereactive load. Reactive lodes are related to motors and rotational loads. There are several solid state converters inuse in power system operation, such as hvdc converters. Analysis of reactive power in power system electrical. Reactive power loads must be supplied either locally from customerowned devices or from the system itself.
Real and reactive power flow control using flexible ac transmission system connected to. As the dc current increases, than reactive power supplied by sg increases, it means the energy exchange of generator is increased with the load. A line that is open on the other end without load is like a capacitor and is a source of capacitive leading reactive power. The circulation of reactive power in the electrical network has major technical and economic consequences. Utilities usually charge a penalty fee to customers with power factors less than 0. For simplicity, the line is represented only by its.
It is usually a fast acting static var compensator. Yongan deng, masc student at concordia university 1. Jun 21, 2016 for understanding the relationship between the reactive power flow in a transmission line and voltage drop, we will consider short transmission line for simplicity. For improving the performance of a ac power system, the reactive is to be managed in a efficient way, this is known as reactive power compensation. When the line resistance is factored in, the answers for reactive power vary immensely. Reactive power control in electrical power transmission system. Although in alternating power system, reactive power always comes in to picture. Transmission of reactive power will load more the lines, which in turn will introduce more reactive power. Electrical system bureau of energy efficiency 6 recorded and billed for in some utilities, because this would affect the load on the utility. The circuit diagram when statcom is connected at the middle of the long transmission line is shown in fig 8.
Reactive power and voltage relationship in power transmission. The increased electric power consumption causes transmission lines to be driven close to or even beyond their transfer capacities resulting in overloaded lines and congestions. However, we find the concept of reactive power little bit confusing because reactive power does not contribute in doing useful work. If we subtract reactive power flowing out of one winding of a 2winding trnasformer to reactive power flowing into the other winding, the difference is found by the sum of all the i2x within the reactive. An inductor is a coil of wire that is used to make motors. This implies that the reactive power generated from the line charging is less than.
Principles for efficient and reliable reactive power. It is considered as the most refined power flow control technique. It constitutes voltage and current loading of circuits but does not result in an average active power consumption and is, in fact, an important component in all ac power. Reactive power are used to build up magnetic fields. It also must supply the reactive losses on transmission facilities. For short transmission line resistance and reactance of line is assumed lumped. Show full abstract neural networks anns to control reactive power generated by long transmission line over wide range so as to maintain constant voltage profile at the receiving end. Generally, active power flows from high voltage angle to lower voltage angle and reactive power flows from higher voltage magnitude to lower voltage magnitude.
I calculated it first without factoring in the line resistance rl0 then got the result for q as. Bus1 is connected with infinite bus with a long transmission line. Reactive power is provided by generators, synchronous condensers, or. Feb 14, 2018 when it comes to the dispatchable reactive power that can be provided by the distribution system, the net values attributed to the transmission buses should be considered.
Apparent power is measured in va, kva, mva power factor cos. This reduces number of switching operations in other reactive power compensation equipment. It comprises of a series and a shunt converter connected by a dc link capacitor, that can all together complete the role of transmission line real reactive power flow control. The demand for this reactive power is mainly originated from the inductive load connected to the system. Pdf reactive power control in transmission system using. In actual dc transmission projects, actual reactive power consumption of the converter during operation is not constant but varies randomly due to the following factors. How much reactive power and which direction it is flowing on a transmission line depends on how different these two times are. Jose matias high voltage components reactive power compensation. Similarly the connections are made when the svc is connected at the sending end and receiving end of the long transmission line shown in figure 6. Similarly the connections are made when the svc is connected at the. No active power can flow in the ac transmission lines without reactive power. For the same active power p, a higher reactive power means a higher apparent power, and thus a higher current must be supplied. Since most loads are inductive and consume lagging reactive power, the compensation required is usually supplied by leading reactive power. The transmission system needs reactive power to support system voltages to allow for transport of real power across transmission lines.
By reactive power compensation we can control the power factor and reduce the consumption of electricity. As a result of the april 2004 report and recommendations of the. It is almost universal for some of the reactive load to be compensated locally as power factor correction. The consumption of the reactive power by transmission lines increases with the square of current. If the power demand is less than reactive power supplied, the load voltage rises to a higher level which leads to automatic tripping of transmission equipments, low power factor, insulation failures of the cables and windings of various mechanical devices. However, when the transmission line is with upfc or sssc, the power. Two extreme examples of the time relationship between voltage and current are found in inductors and capacitors. Pdf reactive power compensation of transmission lines. Determine consumed power from active reactive components in energy meter.
404 1405 719 165 243 1386 611 776 1539 412 1482 813 828 1420 1043 864 1379 1382 1026 935 159 1352 138 1200 1257 1476 406 94 793 516